{"id":45361,"date":"2022-02-18T09:44:49","date_gmt":"2022-02-18T14:44:49","guid":{"rendered":"https:\/\/techkon.datacolor.com\/mas-alla-del-densitometro-portatil\/"},"modified":"2026-10-13T14:33:29","modified_gmt":"2026-10-13T18:33:29","slug":"mas-alla-del-densitometro-portatil","status":"publish","type":"post","link":"https:\/\/techkon.datacolor.com\/es\/mas-alla-del-densitometro-portatil\/","title":{"rendered":"M\u00e1s all\u00e1 del densit\u00f3metro port\u00e1til"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"45361\" class=\"elementor elementor-45361 elementor-27330\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-8225f33 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"8225f33\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-679d711\" data-id=\"679d711\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-aaa3c49 elementor-widget elementor-widget-text-editor\" data-id=\"aaa3c49\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p align=\"center\"><b><span style=\"font-size: 20.0pt\">M\u00e1s all\u00e1 del densit\u00f3metro port\u00e1til &#8211; Parte I<\/span><\/b><\/p>\n<p>Aunque los densit\u00f3metros port\u00e1tiles ya se han adoptado en muchas salas de impresi\u00f3n flexogr\u00e1fica, es importante recordar que estos dispositivos no miden realmente el <em>color<\/em> y, por lo tanto, son incapaces de informar sobre la precisi\u00f3n de los colores de marca o directos en prensa.&nbsp; Lo mejor que pueden hacer los densit\u00f3metros es medir e informar sobre las densidades (espesor de la pel\u00edcula de tinta) de las \u00e1reas de color s\u00f3lido y el aumento del valor tonal (TVI) de las \u00e1reas de puntos de semitonos.&nbsp; Aunque ambas son m\u00e9tricas de impresi\u00f3n muy importantes y pueden utilizarse sin duda para establecer cierto nivel de control de procesos en la sala de impresi\u00f3n, el problema es que muchos clientes de marca han empezado a especificar la precisi\u00f3n de color utilizando valores CIELab medidos junto con valores deltaE como tolerancias aceptables en cuanto a la precisi\u00f3n de color.&nbsp; Por lo tanto, los operarios de prensa equipados \u00fanicamente con densit\u00f3metros no pueden saber si se han alcanzado las especificaciones de color de marca o los cambios de color precisos que son necesarios para cumplir estas especificaciones.&nbsp; En estas situaciones, con solo un densit\u00f3metro port\u00e1til, los operarios deben seguir confiando en sus ojos tanto durante la preparaci\u00f3n para igualar los colores como durante la tirada de producci\u00f3n para garantizar la consistencia del color.&nbsp; El peligro aqu\u00ed son tiempos de preparaci\u00f3n m\u00e1s largos, color que nunca alcanza la especificaci\u00f3n y color inconsistente a lo largo de la tirada, lo que puede llevar a rechazos del cliente, reimpresiones de trabajos, aumento de residuos y, en \u00faltima instancia, menor rentabilidad para el impresor.<\/p>\n<p>Entonces, \u00bfqu\u00e9 puede hacer un impresor para mejorar su eficiencia en la sala de impresi\u00f3n y recuperar su rentabilidad?&nbsp; Pues bien, la respuesta no es diferente de c\u00f3mo los impresores han aumentado su productividad y rentabilidad en otras partes de su flujo de trabajo durante las \u00faltimas d\u00e9cadas.&nbsp; En pocas palabras, los impresores de envases deben adoptar herramientas m\u00e1s nuevas que empleen el uso de la ciencia y la tecnolog\u00eda para eliminar las \u00abconjeturas\u00bb sobre el color para los operarios de prensa y garantizar un proceso de fabricaci\u00f3n de impresi\u00f3n en color mucho m\u00e1s predecible, preciso y repetible.&nbsp; Este es exactamente el tema de esta serie de blogs de 3 partes que examinar\u00e1 las opciones tecnol\u00f3gicas \u00abBuena\u00bb, \u00abMejor\u00bb y \u00ab\u00d3ptima\u00bb que se est\u00e1n implementando hoy en d\u00eda en las salas de impresi\u00f3n de envases:<\/p>\n<ul>\n<li style=\"list-style-type: none\">\n<ul>\n<li><b>Buena<\/b>: Sustituir los densit\u00f3metros por espectrofot\u00f3metros<\/li>\n<li><b>Mejor<\/b>: A\u00f1adir software de calidad de color junto a la prensa<\/li>\n<li><b>\u00d3ptima<\/b>: Automatizar las mediciones de color con un espectrofot\u00f3metro en l\u00ednea<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<p>Esta semana, examinamos la soluci\u00f3n \u00abBuena\u00bb para aumentar la precisi\u00f3n de color, acortar los tiempos de preparaci\u00f3n y permitir que los impresores de envases recuperen su rentabilidad.<\/p>\n<p><strong>Buena: Sustituir los densit\u00f3metros por espectrofot\u00f3metros<\/strong><\/p>\n<p><strong>Descripci\u00f3n general:<\/strong><\/p>\n<p>Sencillamente, los densit\u00f3metros port\u00e1tiles no miden el color y son incapaces de informar sobre los valores <a href=\"https:\/\/en.wikipedia.org\/wiki\/CIELAB_color_space\">CIELab<\/a> de un color. Esto tambi\u00e9n significa que los densit\u00f3metros no pueden describir objetivamente c\u00f3mo el sistema visual humano percibe un color ni cuantificar las diferencias percibidas entre dos tonos de colores utilizando una f\u00f3rmula \u2206E. Por esta raz\u00f3n, cambiar de densit\u00f3metros a espectrofot\u00f3metros es absolutamente imprescindible para los impresores de envases. De lo contrario, los operarios de prensa no pueden saber cu\u00e1ndo se han alcanzado las especificaciones contractuales de marca o qu\u00e9 cambios de color se requieren para cumplirlas.<\/p>\n<p>Realizar este cambio es relativamente f\u00e1cil para los operarios de prensa porque los espectrofot\u00f3metros a\u00fan pueden informar sobre todas las funciones densitom\u00e9tricas habituales como la densidad de tinta s\u00f3lida y el TVI, que son m\u00e9tricas importantes de control de procesos, y los instrumentos se operan y manejan de la misma manera que los densit\u00f3metros.&nbsp; Sin embargo, adem\u00e1s de informar sobre valores densitom\u00e9tricos y colorim\u00e9tricos para las muestras medidas, los espectrofot\u00f3metros tienen muchas m\u00e1s caracter\u00edsticas y funciones que pueden ayudar a guiar a los operarios hacia coincidencias de color m\u00e1s r\u00e1pidas y precisas.<\/p>\n<p><strong>Flujo de trabajo:<\/strong><\/p>\n<p>El flujo de trabajo utilizando un espectrofot\u00f3metro para comprobar la precisi\u00f3n de color es extremadamente similar al de utilizar un densit\u00f3metro port\u00e1til.&nbsp; En una prensa flexogr\u00e1fica, la prensa se detiene y se corta una muestra del rollo, mientras que en una prensa de hojas, simplemente se extrae una muestra de la pila de salida.&nbsp; La muestra impresa se coloca entonces sobre una superficie plana donde puede medirse con el espectrofot\u00f3metro.&nbsp; Ahora el operario de prensa selecciona el modo de medici\u00f3n en el instrumento (Densidad, TVI, Opacidad CIELab, etc.), alinea la apertura de medici\u00f3n sobre la muestra que se va a medir, inicia la medici\u00f3n y los resultados se mostrar\u00e1n en la pantalla del instrumento.&nbsp; Si el usuario desea ver otra informaci\u00f3n de medici\u00f3n de esta misma muestra, deber\u00e1 cambiar el modo de visualizaci\u00f3n en el instrumento.<\/p>\n<p><strong>Ventajas principales:<\/strong>&nbsp;<\/p>\n<ul>\n<li>Los espectrofot\u00f3metros pueden almacenar miles de colores de referencia (incluidas las bibliotecas Pantone) dentro del instrumento y las <a href=\"https:\/\/en.wikipedia.org\/wiki\/Color_difference\">diferencias de color (\u2206E)<\/a> entre una muestra impresa y un color de referencia o de marca pueden mostrarse autom\u00e1ticamente<\/li>\n<li>Los espectrofot\u00f3metros pueden recomendar ajustes de densidad precisos para lograr el \u2206E m\u00e1s bajo en prensa para un color particular. Esta es una caracter\u00edstica valiosa que puede reducir dr\u00e1sticamente los tiempos de preparaci\u00f3n de la sala de impresi\u00f3n porque se muestra al operario el valor de densidad preciso que se requiere para cada color en el trabajo para lograr el \u2206E m\u00e1s bajo. &nbsp; En algunos casos, esto puede indicar que debe cambiarse un rodillo anilox y en otros casos puede indicar problemas de tinta que no pueden superarse completamente solo con ajustes de densidad.&nbsp; En cualquier caso, esta es informaci\u00f3n valiosa para el operario y puede ahorrar tiempo y materiales considerables.&nbsp; <span style=\"background: yellow;color: unset\">Considere el ejemplo siguiente donde el instrumento indica que un aumento de densidad de 0,18 reducir\u00e1 en gran medida el \u2206E actual de 10,2 a un \u2206E de solo 0,9 para esta coincidencia con Pantone 647 C<\/span><\/li>\n<\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-ceb3a24 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"ceb3a24\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-d170245\" data-id=\"d170245\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-5e0b5af elementor-widget elementor-widget-image\" data-id=\"5e0b5af\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<a href=\"https:\/\/techkon.datacolor.com\/products-2\/spectrodens4-densitometer\/\">\n\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"780\" height=\"474\" src=\"https:\/\/techkon.datacolor.com\/wp-content\/uploads\/2022\/02\/SpectroDensDensityMatch.png\" class=\"attachment-large size-large wp-image-45363\" alt=\"De densit\u00f3metro a espectrofot\u00f3metro - SpectroDens Density Match\" srcset=\"https:\/\/techkon.datacolor.com\/wp-content\/uploads\/2022\/02\/SpectroDensDensityMatch.png 780w, https:\/\/techkon.datacolor.com\/wp-content\/uploads\/2022\/02\/SpectroDensDensityMatch-300x182.png 300w, https:\/\/techkon.datacolor.com\/wp-content\/uploads\/2022\/02\/SpectroDensDensityMatch-768x467.png 768w, https:\/\/techkon.datacolor.com\/wp-content\/uploads\/2022\/02\/SpectroDensDensityMatch-150x91.png 150w, https:\/\/techkon.datacolor.com\/wp-content\/uploads\/2022\/02\/SpectroDensDensityMatch-200x122.png 200w, https:\/\/techkon.datacolor.com\/wp-content\/uploads\/2022\/02\/SpectroDensDensityMatch-250x152.png 250w, https:\/\/techkon.datacolor.com\/wp-content\/uploads\/2022\/02\/SpectroDensDensityMatch-327x199.png 327w, https:\/\/techkon.datacolor.com\/wp-content\/uploads\/2022\/02\/SpectroDensDensityMatch-696x423.png 696w, https:\/\/techkon.datacolor.com\/wp-content\/uploads\/2022\/02\/SpectroDensDensityMatch-400x243.png 400w\" sizes=\"(max-width: 780px) 100vw, 780px\" \/>\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-9003a02 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"9003a02\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-a3ffec3\" data-id=\"a3ffec3\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-31a9ca2 elementor-widget elementor-widget-text-editor\" data-id=\"31a9ca2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><em>Techkon SpectroDens ilustrando el cambio de densidad requerido para lograr la coincidencia de \u2206E m\u00e1s baja<\/em><\/p><p> <\/p><ul><li>Los espectrofot\u00f3metros suelen tener una visualizaci\u00f3n gr\u00e1fica de las diferencias de color que indica si la muestra impresa es demasiado roja, demasiado azul, demasiado amarilla, etc., lo que puede ser muy \u00fatil si el operario de prensa decide que necesita modificar o \u00abtonificar\u00bb la tinta en prensa.<\/li><li>Las condiciones de impresi\u00f3n de referencia <a href=\"https:\/\/connect.idealliance.org\/g7\/home\">G7<\/a> e ISO est\u00e1n almacenadas en la mayor\u00eda de los espectrofot\u00f3metros junto a la prensa, lo que puede proporcionar indicaci\u00f3n de APROBADO\/NO APROBADO seg\u00fan estas referencias y cambios recomendados para cumplir con estos est\u00e1ndares<\/li><li>El c\u00e1lculo de la opacidad de la tinta est\u00e1 incluido y es invaluable al imprimir tinta blanca sobre sustratos transparentes donde se requieren coincidencias precisas de colores de proceso y directos<\/li><li>Aunque todav\u00eda es relativamente nuevo, SCTV, tambi\u00e9n conocido como Valor Tonal de Color Directo (ISO 20654:2017), es una nueva f\u00f3rmula que los espectrofot\u00f3metros pueden utilizar para calcular el valor tonal (TV) o el porcentaje de punto de cualquier tinta de color directo bas\u00e1ndose en mediciones de color en lugar de valores de densidad CMYK. El resultado final son mediciones de TV o TVI m\u00e1s precisas que permiten curvas tonales visualmente m\u00e1s lineales para colores directos con una previsibilidad enormemente mejorada en prensa. <\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-116e3d5 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"116e3d5\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-87c184d\" data-id=\"87c184d\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap\">\n\t\t\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-3567ff4\" data-id=\"3567ff4\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-3fd5d91 elementor-widget elementor-widget-image\" data-id=\"3fd5d91\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<a href=\"https:\/\/techkon.datacolor.com\/es\/contacto\/\">\n\t\t\t\t\t\t\t<img decoding=\"async\" width=\"248\" height=\"70\" src=\"https:\/\/techkon.datacolor.com\/wp-content\/uploads\/2022\/02\/RFQbutton.png\" class=\"attachment-large size-large wp-image-45245\" alt=\"\" srcset=\"https:\/\/techkon.datacolor.com\/wp-content\/uploads\/2022\/02\/RFQbutton.png 248w, https:\/\/techkon.datacolor.com\/wp-content\/uploads\/2022\/02\/RFQbutton-150x42.png 150w, https:\/\/techkon.datacolor.com\/wp-content\/uploads\/2022\/02\/RFQbutton-200x56.png 200w\" sizes=\"(max-width: 248px) 100vw, 248px\" \/>\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-c47ce09 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"c47ce09\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-3d167b6\" data-id=\"3d167b6\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-0edb284 elementor-widget elementor-widget-text-editor\" data-id=\"0edb284\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p> <br>La pr\u00f3xima semana, retomaremos donde lo dejamos y examinaremos la soluci\u00f3n \u00abMejor\u00bb que un densit\u00f3metro port\u00e1til para el control de calidad de color junto a la prensa con las ventajas de integrar software de calidad de color que se utiliza junto con un espectrofot\u00f3metro de sala de impresi\u00f3n. Si alguien tiene alguna pregunta o desea obtener m\u00e1s informaci\u00f3n sobre los productos de Techkon, no dude en llamarnos en cualquier momento. Adem\u00e1s, para aquellos lectores que asistir\u00e1n a la conferencia Infoflex de FTA en marzo, programen una cita con nosotros para una demostraci\u00f3n de producto en vivo individual o simplemente pasen por el stand a saludar. Hablamos con todos ustedes la pr\u00f3xima semana\u2026   <\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-2a2169a elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"2a2169a\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-1b7148b\" data-id=\"1b7148b\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-f304eaf elementor-widget elementor-widget-spacer\" data-id=\"f304eaf\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"spacer.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-spacer\">\n\t\t\t<div class=\"elementor-spacer-inner\"><\/div>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-0abb1cd elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"0abb1cd\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-b4eef69\" data-id=\"b4eef69\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-9da9279 elementor-widget elementor-widget-text-editor\" data-id=\"9da9279\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\tPuede leer las otras dos partes de este blog aqu\u00ed:\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-b7b3dc6 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"b7b3dc6\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-dfd0115\" data-id=\"dfd0115\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-03ac617 elementor-widget elementor-widget-image\" data-id=\"03ac617\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<a href=\"https:\/\/techkon.datacolor.com\/es\/mas-alla-del-densitometro-parte-2\/\">\n\t\t\t\t\t\t\t<img decoding=\"async\" src=\"https:\/\/techkon.datacolor.com\/wp-content\/uploads\/elementor\/thumbs\/part2small-plmdm8gw1cxtaco3hm0h4hxspywwzsti8tes8lpjls.png\" title=\"parte2peque\u00f1a\" alt=\"parte2peque\u00f1a\" loading=\"lazy\" \/>\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-fdc99b2\" data-id=\"fdc99b2\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-da0beed elementor-widget elementor-widget-image\" data-id=\"da0beed\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<a href=\"https:\/\/techkon.datacolor.com\/beyond-the-densitometer-3\/\">\n\t\t\t\t\t\t\t<img decoding=\"async\" src=\"https:\/\/techkon.datacolor.com\/wp-content\/uploads\/elementor\/thumbs\/part3small-plmdmbaelv1o96k0158ctz86i4j0mw4p97d8ofld34.png\" title=\"part3small\" alt=\"part3small\" loading=\"lazy\" \/>\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-cd95b02 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"cd95b02\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-c4a414a\" data-id=\"c4a414a\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap\">\n\t\t\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>M\u00e1s all\u00e1 del densit\u00f3metro port\u00e1til &#8211; Parte I Aunque los densit\u00f3metros port\u00e1tiles ya se han adoptado en muchas salas de impresi\u00f3n flexogr\u00e1fica, es importante recordar que estos dispositivos no miden realmente el color y, por lo tanto, son incapaces de informar sobre la precisi\u00f3n de los colores de marca o directos en prensa.&nbsp; Lo mejor que pueden hacer los densit\u00f3metros es medir e informar sobre las densidades (espesor de la pel\u00edcula de tinta) de las&#8230;  <\/p>\n<div class=\"read-more\"><a class=\"excerpt-read-more\" href=\"https:\/\/techkon.datacolor.com\/es\/mas-alla-del-densitometro-portatil\/\" title=\"Continue reading M\u00e1s all\u00e1 del densit\u00f3metro port\u00e1til\">Leer m\u00e1s<i class=\"fa fa-angle-right\"><\/i><\/a><\/div>\n","protected":false},"author":27,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[384],"tags":[],"class_list":["post-45361","post","type-post","status-publish","format-standard","hentry","category-sin-categorizar"],"acf":[],"contentshake_article_id":"","yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v28.4 (Yoast SEO v28.7) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>M\u00e1s all\u00e1 del densit\u00f3metro port\u00e1til | Techkon<\/title>\n<meta name=\"description\" content=\"La primera parte de una serie de 3 explora el cambio del densit\u00f3metro port\u00e1til a los espectrofot\u00f3metros en las salas de impresi\u00f3n de envases.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/techkon.datacolor.com\/es\/mas-alla-del-densitometro-portatil\/\" \/>\n<meta property=\"og:locale\" content=\"es_ES\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"M\u00e1s all\u00e1 del densit\u00f3metro port\u00e1til\" \/>\n<meta property=\"og:description\" content=\"La primera parte de una serie de 3 explora el cambio del densit\u00f3metro port\u00e1til a los espectrofot\u00f3metros en las salas de impresi\u00f3n de envases.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/techkon.datacolor.com\/es\/mas-alla-del-densitometro-portatil\/\" \/>\n<meta property=\"og:site_name\" content=\"Techkon\" \/>\n<meta property=\"article:publisher\" content=\"http:\/\/www.facebook.com\/TechkonUSA\" \/>\n<meta property=\"article:published_time\" content=\"2022-02-18T14:44:49+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-10-13T18:33:29+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/techkon.datacolor.com\/wp-content\/uploads\/2022\/02\/SpectroDensDensityMatch.png\" \/>\n\t<meta property=\"og:image:width\" content=\"780\" \/>\n\t<meta property=\"og:image:height\" content=\"474\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Steve Rankin\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/techkon.datacolor.com\\\/es\\\/mas-alla-del-densitometro-portatil\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/techkon.datacolor.com\\\/es\\\/mas-alla-del-densitometro-portatil\\\/\"},\"author\":{\"name\":\"Steve Rankin\",\"@id\":\"https:\\\/\\\/techkon.datacolor.com\\\/es\\\/#\\\/schema\\\/person\\\/dda671f4838d0e47b75874771d5c8f39\"},\"headline\":\"M\u00e1s all\u00e1 del densit\u00f3metro port\u00e1til\",\"datePublished\":\"2022-02-18T14:44:49+00:00\",\"dateModified\":\"2026-10-13T18:33:29+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/techkon.datacolor.com\\\/es\\\/mas-alla-del-densitometro-portatil\\\/\"},\"wordCount\":1468,\"publisher\":{\"@id\":\"https:\\\/\\\/techkon.datacolor.com\\\/es\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/techkon.datacolor.com\\\/es\\\/mas-alla-del-densitometro-portatil\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/techkon.datacolor.com\\\/wp-content\\\/uploads\\\/2022\\\/02\\\/SpectroDensDensityMatch.png\",\"articleSection\":[\"Sin categorizar\"],\"inLanguage\":\"es\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/techkon.datacolor.com\\\/es\\\/mas-alla-del-densitometro-portatil\\\/\",\"url\":\"https:\\\/\\\/techkon.datacolor.com\\\/es\\\/mas-alla-del-densitometro-portatil\\\/\",\"name\":\"M\u00e1s all\u00e1 del densit\u00f3metro port\u00e1til | Techkon\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/techkon.datacolor.com\\\/es\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/techkon.datacolor.com\\\/es\\\/mas-alla-del-densitometro-portatil\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/techkon.datacolor.com\\\/es\\\/mas-alla-del-densitometro-portatil\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/techkon.datacolor.com\\\/wp-content\\\/uploads\\\/2022\\\/02\\\/SpectroDensDensityMatch.png\",\"datePublished\":\"2022-02-18T14:44:49+00:00\",\"dateModified\":\"2026-10-13T18:33:29+00:00\",\"description\":\"La primera parte de una serie de 3 explora el cambio del densit\u00f3metro port\u00e1til a los espectrofot\u00f3metros en las salas de impresi\u00f3n de envases.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/techkon.datacolor.com\\\/es\\\/mas-alla-del-densitometro-portatil\\\/#breadcrumb\"},\"inLanguage\":\"es\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/techkon.datacolor.com\\\/es\\\/mas-alla-del-densitometro-portatil\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\\\/\\\/techkon.datacolor.com\\\/es\\\/mas-alla-del-densitometro-portatil\\\/#primaryimage\",\"url\":\"https:\\\/\\\/techkon.datacolor.com\\\/wp-content\\\/uploads\\\/2022\\\/02\\\/SpectroDensDensityMatch.png\",\"contentUrl\":\"https:\\\/\\\/techkon.datacolor.com\\\/wp-content\\\/uploads\\\/2022\\\/02\\\/SpectroDensDensityMatch.png\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/techkon.datacolor.com\\\/es\\\/mas-alla-del-densitometro-portatil\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Inicio\",\"item\":\"https:\\\/\\\/techkon.datacolor.com\\\/es\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"M\u00e1s all\u00e1 del densit\u00f3metro port\u00e1til\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/techkon.datacolor.com\\\/es\\\/#website\",\"url\":\"https:\\\/\\\/techkon.datacolor.com\\\/es\\\/\",\"name\":\"Densitometers for Print and Packaging | Techkon\",\"description\":\"Spectrophotometers and Densitometers for Print and Packaging\",\"publisher\":{\"@id\":\"https:\\\/\\\/techkon.datacolor.com\\\/es\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/techkon.datacolor.com\\\/es\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"es\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/techkon.datacolor.com\\\/es\\\/#organization\",\"name\":\"Techkon USA\",\"url\":\"https:\\\/\\\/techkon.datacolor.com\\\/es\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\\\/\\\/techkon.datacolor.com\\\/es\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"http:\\\/\\\/techkon.datacolor.com\\\/wp-content\\\/uploads\\\/2016\\\/06\\\/techkon-signature-logoCLEARER.jpg\",\"contentUrl\":\"http:\\\/\\\/techkon.datacolor.com\\\/wp-content\\\/uploads\\\/2016\\\/06\\\/techkon-signature-logoCLEARER.jpg\",\"width\":150,\"height\":26,\"caption\":\"Techkon USA\"},\"image\":{\"@id\":\"https:\\\/\\\/techkon.datacolor.com\\\/es\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"http:\\\/\\\/www.facebook.com\\\/TechkonUSA\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/techkon.datacolor.com\\\/es\\\/#\\\/schema\\\/person\\\/dda671f4838d0e47b75874771d5c8f39\",\"name\":\"Steve Rankin\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/b89539100a677c310dca27128b0049a621e4022709d9e187feb057400a11f1b4?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/b89539100a677c310dca27128b0049a621e4022709d9e187feb057400a11f1b4?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/b89539100a677c310dca27128b0049a621e4022709d9e187feb057400a11f1b4?s=96&d=mm&r=g\",\"caption\":\"Steve Rankin\"},\"sameAs\":[\"http:\\\/\\\/techkon.datacolor.com\"],\"url\":\"https:\\\/\\\/techkon.datacolor.com\\\/es\\\/author\\\/srankin\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"M\u00e1s all\u00e1 del densit\u00f3metro port\u00e1til | Techkon","description":"La primera parte de una serie de 3 explora el cambio del densit\u00f3metro port\u00e1til a los espectrofot\u00f3metros en las salas de impresi\u00f3n de envases.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/techkon.datacolor.com\/es\/mas-alla-del-densitometro-portatil\/","og_locale":"es_ES","og_type":"article","og_title":"M\u00e1s all\u00e1 del densit\u00f3metro port\u00e1til","og_description":"La primera parte de una serie de 3 explora el cambio del densit\u00f3metro port\u00e1til a los espectrofot\u00f3metros en las salas de impresi\u00f3n de envases.","og_url":"https:\/\/techkon.datacolor.com\/es\/mas-alla-del-densitometro-portatil\/","og_site_name":"Techkon","article_publisher":"http:\/\/www.facebook.com\/TechkonUSA","article_published_time":"2022-02-18T14:44:49+00:00","article_modified_time":"2026-10-13T18:33:29+00:00","og_image":[{"width":780,"height":474,"url":"https:\/\/techkon.datacolor.com\/wp-content\/uploads\/2022\/02\/SpectroDensDensityMatch.png","type":"image\/png"}],"author":"Steve Rankin","twitter_card":"summary_large_image","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/techkon.datacolor.com\/es\/mas-alla-del-densitometro-portatil\/#article","isPartOf":{"@id":"https:\/\/techkon.datacolor.com\/es\/mas-alla-del-densitometro-portatil\/"},"author":{"name":"Steve Rankin","@id":"https:\/\/techkon.datacolor.com\/es\/#\/schema\/person\/dda671f4838d0e47b75874771d5c8f39"},"headline":"M\u00e1s all\u00e1 del densit\u00f3metro port\u00e1til","datePublished":"2022-02-18T14:44:49+00:00","dateModified":"2026-10-13T18:33:29+00:00","mainEntityOfPage":{"@id":"https:\/\/techkon.datacolor.com\/es\/mas-alla-del-densitometro-portatil\/"},"wordCount":1468,"publisher":{"@id":"https:\/\/techkon.datacolor.com\/es\/#organization"},"image":{"@id":"https:\/\/techkon.datacolor.com\/es\/mas-alla-del-densitometro-portatil\/#primaryimage"},"thumbnailUrl":"https:\/\/techkon.datacolor.com\/wp-content\/uploads\/2022\/02\/SpectroDensDensityMatch.png","articleSection":["Sin categorizar"],"inLanguage":"es"},{"@type":"WebPage","@id":"https:\/\/techkon.datacolor.com\/es\/mas-alla-del-densitometro-portatil\/","url":"https:\/\/techkon.datacolor.com\/es\/mas-alla-del-densitometro-portatil\/","name":"M\u00e1s all\u00e1 del densit\u00f3metro port\u00e1til | Techkon","isPartOf":{"@id":"https:\/\/techkon.datacolor.com\/es\/#website"},"primaryImageOfPage":{"@id":"https:\/\/techkon.datacolor.com\/es\/mas-alla-del-densitometro-portatil\/#primaryimage"},"image":{"@id":"https:\/\/techkon.datacolor.com\/es\/mas-alla-del-densitometro-portatil\/#primaryimage"},"thumbnailUrl":"https:\/\/techkon.datacolor.com\/wp-content\/uploads\/2022\/02\/SpectroDensDensityMatch.png","datePublished":"2022-02-18T14:44:49+00:00","dateModified":"2026-10-13T18:33:29+00:00","description":"La primera parte de una serie de 3 explora el cambio del densit\u00f3metro port\u00e1til a los espectrofot\u00f3metros en las salas de impresi\u00f3n de envases.","breadcrumb":{"@id":"https:\/\/techkon.datacolor.com\/es\/mas-alla-del-densitometro-portatil\/#breadcrumb"},"inLanguage":"es","potentialAction":[{"@type":"ReadAction","target":["https:\/\/techkon.datacolor.com\/es\/mas-alla-del-densitometro-portatil\/"]}]},{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/techkon.datacolor.com\/es\/mas-alla-del-densitometro-portatil\/#primaryimage","url":"https:\/\/techkon.datacolor.com\/wp-content\/uploads\/2022\/02\/SpectroDensDensityMatch.png","contentUrl":"https:\/\/techkon.datacolor.com\/wp-content\/uploads\/2022\/02\/SpectroDensDensityMatch.png"},{"@type":"BreadcrumbList","@id":"https:\/\/techkon.datacolor.com\/es\/mas-alla-del-densitometro-portatil\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Inicio","item":"https:\/\/techkon.datacolor.com\/es\/"},{"@type":"ListItem","position":2,"name":"M\u00e1s all\u00e1 del densit\u00f3metro port\u00e1til"}]},{"@type":"WebSite","@id":"https:\/\/techkon.datacolor.com\/es\/#website","url":"https:\/\/techkon.datacolor.com\/es\/","name":"Densitometers for Print and Packaging | Techkon","description":"Spectrophotometers and Densitometers for Print and Packaging","publisher":{"@id":"https:\/\/techkon.datacolor.com\/es\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/techkon.datacolor.com\/es\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"es"},{"@type":"Organization","@id":"https:\/\/techkon.datacolor.com\/es\/#organization","name":"Techkon USA","url":"https:\/\/techkon.datacolor.com\/es\/","logo":{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/techkon.datacolor.com\/es\/#\/schema\/logo\/image\/","url":"http:\/\/techkon.datacolor.com\/wp-content\/uploads\/2016\/06\/techkon-signature-logoCLEARER.jpg","contentUrl":"http:\/\/techkon.datacolor.com\/wp-content\/uploads\/2016\/06\/techkon-signature-logoCLEARER.jpg","width":150,"height":26,"caption":"Techkon USA"},"image":{"@id":"https:\/\/techkon.datacolor.com\/es\/#\/schema\/logo\/image\/"},"sameAs":["http:\/\/www.facebook.com\/TechkonUSA"]},{"@type":"Person","@id":"https:\/\/techkon.datacolor.com\/es\/#\/schema\/person\/dda671f4838d0e47b75874771d5c8f39","name":"Steve Rankin","image":{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/secure.gravatar.com\/avatar\/b89539100a677c310dca27128b0049a621e4022709d9e187feb057400a11f1b4?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/b89539100a677c310dca27128b0049a621e4022709d9e187feb057400a11f1b4?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/b89539100a677c310dca27128b0049a621e4022709d9e187feb057400a11f1b4?s=96&d=mm&r=g","caption":"Steve Rankin"},"sameAs":["http:\/\/techkon.datacolor.com"],"url":"https:\/\/techkon.datacolor.com\/es\/author\/srankin\/"}]}},"_links":{"self":[{"href":"https:\/\/techkon.datacolor.com\/es\/wp-json\/wp\/v2\/posts\/45361","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/techkon.datacolor.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/techkon.datacolor.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/techkon.datacolor.com\/es\/wp-json\/wp\/v2\/users\/27"}],"replies":[{"embeddable":true,"href":"https:\/\/techkon.datacolor.com\/es\/wp-json\/wp\/v2\/comments?post=45361"}],"version-history":[{"count":1,"href":"https:\/\/techkon.datacolor.com\/es\/wp-json\/wp\/v2\/posts\/45361\/revisions"}],"predecessor-version":[{"id":45365,"href":"https:\/\/techkon.datacolor.com\/es\/wp-json\/wp\/v2\/posts\/45361\/revisions\/45365"}],"wp:attachment":[{"href":"https:\/\/techkon.datacolor.com\/es\/wp-json\/wp\/v2\/media?parent=45361"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/techkon.datacolor.com\/es\/wp-json\/wp\/v2\/categories?post=45361"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/techkon.datacolor.com\/es\/wp-json\/wp\/v2\/tags?post=45361"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}