{"id":43801,"date":"2015-05-18T16:51:24","date_gmt":"2015-05-18T20:51:24","guid":{"rendered":"https:\/\/techkon.datacolor.com\/funcion-idealliance\/"},"modified":"2026-10-13T10:13:10","modified_gmt":"2026-10-13T14:13:10","slug":"funcion-idealliance","status":"publish","type":"page","link":"https:\/\/techkon.datacolor.com\/es\/funcion-idealliance\/","title":{"rendered":"Funci\u00f3n Idealliance"},"content":{"rendered":"<div class=\"wpb-content-wrapper\"><p>[vc_row top=\u00bb80px\u00bb bottom=\u00bb30px\u00bb][vc_column][vc_heading h_size=\u00bbh-large\u00bb title=\u00bbCu\u00f1a de control Idealliance\u00bb title_tag=\u00bbh1&#8243; divider=\u00bbdiv-between\u00bb divider_type=\u00bbdiv-wide\u00bb divider_color=\u00bb#00965f\u00bb][vc_empty_space][vc_custom_heading text=\u00bbCompatibilidad de SpectroDens con la cu\u00f1a de control de 3 filas ISO 12647-7 2013&#8243; font_container=\u00bbtag:h5|text_align:left|color:%2342454c\u00bb use_theme_fonts=\u00bbyes\u00bb][vc_empty_space height=\u00bb25px\u00bb][vc_column_text]<span style=\"color: #42454c;\">SpectroDENS ahora es compatible con el escaneo de la cu\u00f1a de control IDEAlliance ISO 12647-7 2013. Esta cu\u00f1a de control es necesaria para la certificaci\u00f3n IDEAlliance de dispositivos de pruebas. Tambi\u00e9n es \u00fatil para controles de calidad de pruebas de preimpresi\u00f3n, as\u00ed como de impresoras\/prensas de producci\u00f3n.  <\/span>[\/vc_column_text][vc_empty_space height=\u00bb35px\u00bb][vc_single_image image=\u00bb43802&#8243; img_size=\u00bbfull\u00bb alignment=\u00bbcenter\u00bb onclick=\u00bbcustom_link\u00bb link=\u00bbhttp:\/\/www.idealliance.org\/downloads\/idealliance-iso-12647-7-3-row-digital-control-wedge-2013&#8243;][vc_empty_space height=\u00bb35px\u00bb][vc_column_text]<span style=\"color: #42454c;\">Los 84 parches en tres filas se pueden escanear en menos de 10 segundos. En la pantalla del dispositivo se muestra un resumen de las diferencias de color respecto a los valores objetivo publicados y los resultados de aprobaci\u00f3n\/reprobaci\u00f3n. El escaneo r\u00e1pido y los resultados resumidos en la pantalla de SpectroDENS le permiten utilizar esta cu\u00f1a de control de manera m\u00e1s eficiente. A continuaci\u00f3n se indican los requisitos y los pasos necesarios para utilizar esta cu\u00f1a de control con SpectroDENS.   <\/span>[\/vc_column_text][\/vc_column][\/vc_row][vc_row top=\u00bb10px\u00bb bottom=\u00bb10px\u00bb][vc_column][vc_accordion collapsible=\u00bbyes\u00bb active_tab=\u00bbfalse\u00bb][vc_accordion_tab title=\u00bbRequisitos\u00bb][vc_column_text]<\/p>\n<h4><span style=\"color: #42454c;\">Requisitos<\/span><\/h4>\n<ol>\n<li><a href=\"http:\/\/software.techkon.com\/SpectroDens%20V8.08%20SD3%20V11.01.tsd\">Descargar el firmware de SpectroDens III<\/a> <span style=\"color: #42454c;\">11.01 o posterior. Instale la actualizaci\u00f3n del firmware en el dispositivo siguiendo estas instrucciones. <\/span><\/li>\n<li><a href=\"http:\/\/software.techkon.com\/SpectroConnect.2.5.1.exe\">Descargue el software SpectroConnect<\/a> <span style=\"color: #42454c;\">2.5.1 o posterior e inst\u00e1lelo en el ordenador si a\u00fan no lo tiene.<\/span><\/li>\n<li><a href=\"http:\/\/www.idealliance.org\/downloads\/idealliance-iso-12647-7-3-row-digital-control-wedge-2013\">Obtener el archivo de imagen objetivo<\/a> <span style=\"color: #42454c;\">para su uso con el trabajo de impresi\u00f3n. La imagen objetivo debe pasar por el mismo proceso que la imagen real en el trabajo de impresi\u00f3n. <\/span><\/li>\n<li><span style=\"color: #42454c;\">Obtenga los archivos de referencia para la cu\u00f1a de control rellenando el formulario en esta p\u00e1gina o envi\u00e1ndonos un correo electr\u00f3nico a<\/span> <a href=\"mailto:service@techkon.datacolor.com\">service@techkon.datacolor.com<\/a>.<\/li>\n<\/ol>\n<p>[\/vc_column_text][\/vc_accordion_tab][vc_accordion_tab title=\u00bbProcedimiento\u00bb][vc_column_text]<\/p>\n<h4><span style=\"color: #42454c;\">Procedimiento<\/span><\/h4>\n<ol>\n<li><span style=\"color: #42454c;\">Configure la condici\u00f3n de medici\u00f3n del SDIII en M1 (D50 incluido UV)<\/span><\/li>\n<li><span style=\"color: #42454c;\">Calibre el SDIII con su baldosa cer\u00e1mica blanca redonda<\/span><\/li>\n<li><span style=\"color: #42454c;\">En el SDIII, seleccione la funci\u00f3n Media Wedge en el panel inferior derecho<\/span><\/li>\n<li><span style=\"color: #42454c;\">Pulse la tecla Intro una segunda vez para seleccionar el archivo de referencia. El nombre del archivo de referencia aparecer\u00e1 en la pantalla Media Wedge. <\/span><\/li>\n<li><span style=\"color: #42454c;\">(Para establecer las tolerancias de aprobaci\u00f3n\/reprobaci\u00f3n, desde la funci\u00f3n Media Wedge vaya a configuraci\u00f3n de medici\u00f3n, pulse INTRO, consulte la configuraci\u00f3n de Media Wedge, pulse INTRO. Establezca las tolerancias deseadas y pulse ESCAPE para salir).<\/span><\/li>\n<li><span style=\"color: #42454c;\">Siguiendo la pantalla gr\u00e1fica, coloque la apertura del SDIII a la izquierda del primer parche<\/span><\/li>\n<li><span style=\"color: #42454c;\">Pulse el bot\u00f3n verde de inicio hasta que aparezca la rueda giratoria en la pantalla<\/span><\/li>\n<li><span style=\"color: #42454c;\">Desplace el SDIII a lo largo de la primera fila y det\u00e9ngase justo a la derecha del \u00faltimo parche<\/span><\/li>\n<li><span style=\"color: #42454c;\">Repita el proceso para la segunda y tercera filas<\/span><\/li>\n<li><span style=\"color: #42454c;\">Aparece un informe resumido en la pantalla del SDIII<\/span><\/li>\n<\/ol>\n<p>[\/vc_column_text][\/vc_accordion_tab][vc_accordion_tab title=\u00bbResultados\u00bb][vc_single_image image=\u00bb43803&#8243; img_size=\u00bbfull\u00bb alignment=\u00bbcenter\u00bb][\/vc_accordion_tab][\/vc_accordion][\/vc_column][\/vc_row][vc_row top=\u00bb30px\u00bb bottom=\u00bb30px\u00bb section_id=\u00bbwhite\u00bb][vc_column][vc_custom_heading text=\u00bbCapturas de pantalla\u00bb font_container=\u00bbtag:h4|text_align:left|color:%2342454c\u00bb use_theme_fonts=\u00bbyes\u00bb][vc_empty_space height=\u00bb25px\u00bb][vc_single_image image=\u00bb43804&#8243; img_size=\u00bbfull\u00bb][\/vc_column][\/vc_row][vc_row top=\u00bb30px\u00bb bottom=\u00bb30px\u00bb section_id=\u00bbvideo\u00bb][vc_column][vc_custom_heading text=\u00bbV\u00eddeo\u00bb font_container=\u00bbtag:h4|text_align:left\u00bb use_theme_fonts=\u00bbyes\u00bb][vc_empty_space height=\u00bb25px\u00bb][vc_video link=\u00bbhttps:\/\/vimeo.com\/134731909&#8243; el_width=\u00bb80&#8243;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h4 style=\"text-align: left;\"><span style=\"color: #42454c;\">Env\u00edenos un correo electr\u00f3nico a service@techkon.datacolor.com o ll\u00e1menos<\/span><br \/>\n<span style=\"color: #42454c;\"> al 978-777-1854 si tiene alguna pregunta.<\/span><\/h4>\n<p>[\/vc_column_text][\/vc_column][\/vc_row]<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>[vc_row top=\u00bb80px\u00bb bottom=\u00bb30px\u00bb][vc_column][vc_heading h_size=\u00bbh-large\u00bb title=\u00bbCu\u00f1a de control Idealliance\u00bb title_tag=\u00bbh1&#8243; divider=\u00bbdiv-between\u00bb divider_type=\u00bbdiv-wide\u00bb divider_color=\u00bb#00965f\u00bb][vc_empty_space][vc_custom_heading text=\u00bbCompatibilidad de SpectroDens con la cu\u00f1a de control de 3 filas ISO 12647-7 2013&#8243; font_container=\u00bbtag:h5|text_align:left|color:%2342454c\u00bb use_theme_fonts=\u00bbyes\u00bb][vc_empty_space height=\u00bb25px\u00bb][vc_column_text]SpectroDENS ahora es compatible con el escaneo de la cu\u00f1a de control IDEAlliance ISO 12647-7 2013. Esta cu\u00f1a de control es necesaria para la certificaci\u00f3n IDEAlliance de dispositivos de pruebas. Tambi\u00e9n es \u00fatil para controles de calidad de pruebas de preimpresi\u00f3n, as\u00ed como de impresoras\/prensas de producci\u00f3n&#8230;.  <\/p>\n<div class=\"read-more\"><a class=\"excerpt-read-more\" href=\"https:\/\/techkon.datacolor.com\/es\/funcion-idealliance\/\" title=\"Continue reading Funci\u00f3n Idealliance\">Leer m\u00e1s<i class=\"fa fa-angle-right\"><\/i><\/a><\/div>\n","protected":false},"author":4421,"featured_media":0,"parent":0,"menu_order":128,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":""},"wf_page_folders":[],"class_list":["post-43801","page","type-page","status-publish","hentry"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v28.4 (Yoast SEO v28.7) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Funci\u00f3n Idealliance | Techkon<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/techkon.datacolor.com\/es\/funcion-idealliance\/\" \/>\n<meta property=\"og:locale\" content=\"es_ES\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Funci\u00f3n Idealliance\" \/>\n<meta property=\"og:description\" content=\"[vc_row top=\u00bb80px\u00bb bottom=\u00bb30px\u00bb][vc_column][vc_heading h_size=\u00bbh-large\u00bb title=\u00bbCu\u00f1a de control Idealliance\u00bb title_tag=\u00bbh1&#8243; divider=\u00bbdiv-between\u00bb divider_type=\u00bbdiv-wide\u00bb divider_color=\u00bb#00965f\u00bb][vc_empty_space][vc_custom_heading text=\u00bbCompatibilidad de SpectroDens con la cu\u00f1a de control de 3 filas ISO 12647-7 2013&#8243; font_container=\u00bbtag:h5|text_align:left|color:%2342454c\u00bb use_theme_fonts=\u00bbyes\u00bb][vc_empty_space height=\u00bb25px\u00bb][vc_column_text]SpectroDENS ahora es compatible con el escaneo de la cu\u00f1a de control IDEAlliance ISO 12647-7 2013. Esta cu\u00f1a de control es necesaria para la certificaci\u00f3n IDEAlliance de dispositivos de pruebas. Tambi\u00e9n es \u00fatil para controles de calidad de pruebas de preimpresi\u00f3n, as\u00ed como de impresoras\/prensas de producci\u00f3n.... Leer m\u00e1s\" \/>\n<meta property=\"og:url\" content=\"https:\/\/techkon.datacolor.com\/es\/funcion-idealliance\/\" \/>\n<meta property=\"og:site_name\" content=\"Techkon\" \/>\n<meta property=\"article:publisher\" content=\"http:\/\/www.facebook.com\/TechkonUSA\" \/>\n<meta property=\"article:modified_time\" content=\"2026-10-13T14:13:10+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/techkon.datacolor.com\\\/es\\\/funcion-idealliance\\\/\",\"url\":\"https:\\\/\\\/techkon.datacolor.com\\\/es\\\/funcion-idealliance\\\/\",\"name\":\"Funci\u00f3n Idealliance | Techkon\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/techkon.datacolor.com\\\/es\\\/#website\"},\"datePublished\":\"2015-05-18T20:51:24+00:00\",\"dateModified\":\"2026-10-13T14:13:10+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/techkon.datacolor.com\\\/es\\\/funcion-idealliance\\\/#breadcrumb\"},\"inLanguage\":\"es\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/techkon.datacolor.com\\\/es\\\/funcion-idealliance\\\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/techkon.datacolor.com\\\/es\\\/funcion-idealliance\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Inicio\",\"item\":\"https:\\\/\\\/techkon.datacolor.com\\\/es\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Funci\u00f3n Idealliance\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/techkon.datacolor.com\\\/es\\\/#website\",\"url\":\"https:\\\/\\\/techkon.datacolor.com\\\/es\\\/\",\"name\":\"Densitometers for Print and Packaging | Techkon\",\"description\":\"Spectrophotometers and Densitometers for Print and Packaging\",\"publisher\":{\"@id\":\"https:\\\/\\\/techkon.datacolor.com\\\/es\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/techkon.datacolor.com\\\/es\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"es\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/techkon.datacolor.com\\\/es\\\/#organization\",\"name\":\"Techkon USA\",\"url\":\"https:\\\/\\\/techkon.datacolor.com\\\/es\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\\\/\\\/techkon.datacolor.com\\\/es\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"http:\\\/\\\/techkon.datacolor.com\\\/wp-content\\\/uploads\\\/2016\\\/06\\\/techkon-signature-logoCLEARER.jpg\",\"contentUrl\":\"http:\\\/\\\/techkon.datacolor.com\\\/wp-content\\\/uploads\\\/2016\\\/06\\\/techkon-signature-logoCLEARER.jpg\",\"width\":150,\"height\":26,\"caption\":\"Techkon USA\"},\"image\":{\"@id\":\"https:\\\/\\\/techkon.datacolor.com\\\/es\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"http:\\\/\\\/www.facebook.com\\\/TechkonUSA\"]}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Funci\u00f3n Idealliance | Techkon","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/techkon.datacolor.com\/es\/funcion-idealliance\/","og_locale":"es_ES","og_type":"article","og_title":"Funci\u00f3n Idealliance","og_description":"[vc_row top=\u00bb80px\u00bb bottom=\u00bb30px\u00bb][vc_column][vc_heading h_size=\u00bbh-large\u00bb title=\u00bbCu\u00f1a de control Idealliance\u00bb title_tag=\u00bbh1&#8243; divider=\u00bbdiv-between\u00bb divider_type=\u00bbdiv-wide\u00bb divider_color=\u00bb#00965f\u00bb][vc_empty_space][vc_custom_heading text=\u00bbCompatibilidad de SpectroDens con la cu\u00f1a de control de 3 filas ISO 12647-7 2013&#8243; font_container=\u00bbtag:h5|text_align:left|color:%2342454c\u00bb use_theme_fonts=\u00bbyes\u00bb][vc_empty_space height=\u00bb25px\u00bb][vc_column_text]SpectroDENS ahora es compatible con el escaneo de la cu\u00f1a de control IDEAlliance ISO 12647-7 2013. Esta cu\u00f1a de control es necesaria para la certificaci\u00f3n IDEAlliance de dispositivos de pruebas. Tambi\u00e9n es \u00fatil para controles de calidad de pruebas de preimpresi\u00f3n, as\u00ed como de impresoras\/prensas de producci\u00f3n.... Leer m\u00e1s","og_url":"https:\/\/techkon.datacolor.com\/es\/funcion-idealliance\/","og_site_name":"Techkon","article_publisher":"http:\/\/www.facebook.com\/TechkonUSA","article_modified_time":"2026-10-13T14:13:10+00:00","twitter_card":"summary_large_image","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/techkon.datacolor.com\/es\/funcion-idealliance\/","url":"https:\/\/techkon.datacolor.com\/es\/funcion-idealliance\/","name":"Funci\u00f3n Idealliance | Techkon","isPartOf":{"@id":"https:\/\/techkon.datacolor.com\/es\/#website"},"datePublished":"2015-05-18T20:51:24+00:00","dateModified":"2026-10-13T14:13:10+00:00","breadcrumb":{"@id":"https:\/\/techkon.datacolor.com\/es\/funcion-idealliance\/#breadcrumb"},"inLanguage":"es","potentialAction":[{"@type":"ReadAction","target":["https:\/\/techkon.datacolor.com\/es\/funcion-idealliance\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/techkon.datacolor.com\/es\/funcion-idealliance\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Inicio","item":"https:\/\/techkon.datacolor.com\/es\/"},{"@type":"ListItem","position":2,"name":"Funci\u00f3n Idealliance"}]},{"@type":"WebSite","@id":"https:\/\/techkon.datacolor.com\/es\/#website","url":"https:\/\/techkon.datacolor.com\/es\/","name":"Densitometers for Print and Packaging | Techkon","description":"Spectrophotometers and Densitometers for Print and Packaging","publisher":{"@id":"https:\/\/techkon.datacolor.com\/es\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/techkon.datacolor.com\/es\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"es"},{"@type":"Organization","@id":"https:\/\/techkon.datacolor.com\/es\/#organization","name":"Techkon USA","url":"https:\/\/techkon.datacolor.com\/es\/","logo":{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/techkon.datacolor.com\/es\/#\/schema\/logo\/image\/","url":"http:\/\/techkon.datacolor.com\/wp-content\/uploads\/2016\/06\/techkon-signature-logoCLEARER.jpg","contentUrl":"http:\/\/techkon.datacolor.com\/wp-content\/uploads\/2016\/06\/techkon-signature-logoCLEARER.jpg","width":150,"height":26,"caption":"Techkon USA"},"image":{"@id":"https:\/\/techkon.datacolor.com\/es\/#\/schema\/logo\/image\/"},"sameAs":["http:\/\/www.facebook.com\/TechkonUSA"]}]}},"_links":{"self":[{"href":"https:\/\/techkon.datacolor.com\/es\/wp-json\/wp\/v2\/pages\/43801","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/techkon.datacolor.com\/es\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/techkon.datacolor.com\/es\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/techkon.datacolor.com\/es\/wp-json\/wp\/v2\/users\/4421"}],"replies":[{"embeddable":true,"href":"https:\/\/techkon.datacolor.com\/es\/wp-json\/wp\/v2\/comments?post=43801"}],"version-history":[{"count":3,"href":"https:\/\/techkon.datacolor.com\/es\/wp-json\/wp\/v2\/pages\/43801\/revisions"}],"predecessor-version":[{"id":43807,"href":"https:\/\/techkon.datacolor.com\/es\/wp-json\/wp\/v2\/pages\/43801\/revisions\/43807"}],"wp:attachment":[{"href":"https:\/\/techkon.datacolor.com\/es\/wp-json\/wp\/v2\/media?parent=43801"}],"wp:term":[{"taxonomy":"wf_page_folders","embeddable":true,"href":"https:\/\/techkon.datacolor.com\/es\/wp-json\/wp\/v2\/wf_page_folders?post=43801"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}